Features
- Self-consumption and feed-in to the grid.
- Programmable supply priority for PV, Battery or Grid.
- Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup.
- User-adjustable battery charging current suits different types of batteries.
- Built-in Timer for various mode of on/off operation.
- Multiple communication for USB, RS-232, Modbus and SNMP.
- Monitoring software for real time status display and control.
- Custom-made firmware by ODM contract.
- Parallel operation up to 6 units.
Specifications
- Phase: 3-phase in / 3-phase out
- Maximum PV Input Power: 14850 W
- Rated Output Power: 10000 W
- Maximum Charging Power: 10000 W
Grid-tie Operation
PV Input (DC)
- Nominal DC Voltage / Maximum DC Voltage: 720 VDC / 900 VDC
- Start-up Voltage / Initial Feeding Voltage: 320 VDC / 350 VDC
- MPP Voltage Range: 350 VDC ~ 850 VDC
- Number of MPP Trackers / Maximum Input Current: 2 / A: 27A, B: 27A
- Number of Strings Per MPP Tracker: A: 2, B: 2
Grid Output (AC)
- Nominal Output Voltage: 230 VAC (p-n) / 400 VAC (p-p)
- Output Voltage Range: 184 – 265 VAC per phase
- Nominal Output Current: 17.4 A per phase
- Power Factor: 0.9 lag ~ 0.9 lead
Efficiency
- Maximum Conversion Efficiency (DC/AC): 96%
- European Efficiency @ Vnominal: 95%
Off-grid Operation
AC Input
- AC Start-up Voltage/Auto Restart Voltage: 120 – 140 VAC /180 VAC
- Acceptable Input Voltage Range: 170 – 290 VAC per phase
- Maximum AC Input Current: 40 A
PV Input (DC)
- Maximum DC power: 16000W
- Maximum DC Voltage: 1000 VDC
- MPP Voltage Range: 350VDC ~ 950VDC
- Number of MPP Trackers/Maximum Input Current: 2 / A: 27A, B: 27A
- Number of Strings Per MPP Tracker: A: 2, B: 2
Battery Mode Output (AC)
- Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
- Output Waveform: Pure Sinewave
- Efficiency (DC to AC): 91%
Hybrid Operation
PV Input (DC)
- Nominal DC Voltage / Maximum DC Voltage: 1000 VDC
- Start-up Voltage / Initial Feeding Voltage: 320 VDC / 350 VDC
- MPP Voltage Range: 350VDC ~ 950 VDC
- Number of MPP Trackers/ Maximum Input Current: 2 / A: 27A, B: 27A
- Number of Strings Per MPP Tracker: A: 2, B: 2
Grid Output (AC)
- Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
- Output Voltage Range: 184 – 265 VAC per phase
- Nominal Output Current: 17.4 A per phase
AC Input
- AC Start-up Voltage/Auto Restart Voltage: 120 – 140 VAC / 180 VAC
- Acceptable Input Voltage Range: 170 – 290 VAC per phase
- Maximum AC Input Current: 40 A
Battery Mode Output (AC)
- Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
- Efficiency (DC to AC): 91%
Battery & Charger
- Nominal DC Voltage: 40~62 VDC
- Maximum Charging Current: 250 A
General
Physical
- Dimension, d x w x h (mm): 255 x 660 x 750
- Net Weight (kgs): 75
Interface
- Communication Port: RS-232, RS-485, USB, CAN and Wi-Fi
- Intelligent Slot: Optional for SNMP and Modbus cards
Environment
- Humidity: 0 ~ 100% RH (Non-condensing)
- Operating Temperature: -25 to 60°C, > 45°C power derating
- Altitude: 0 ~ 1000 m
Reviews
There are no reviews yet.