Features
- Pure sine wave output
- Self-consumption and Feed-in to the grid
- Programmable supply priority for PV , Battery or Grid
- User-adjustable charging current up to 300A
- Programmable multiple operation modes: Grid-tie , off-grid & grid-tie with backup
- Built-in timer for various mode of on/off operation
- Multiple communication for USB, RS-232, Modbus and SNMP
- Monitoring software for real-time status display and control
- Parallel operation up to 6 units
- Warranty: 24 months
Technical Specifications
- Model: InfiniSolar 15KW.
- Phase: 3-phase in/3-phase out.
- Max. PV Input Power: 22500W.
- Rated Output Power: 15000W.
- Maximum Charging Power: 15000W.
Grid-Tie Operation
PV Input (DC)
- Nominal DC Voltage/Max. DC Voltage: 720 VDC/900 VDC.
- Start-up Voltage/Initial Feeding Voltage: 320 VDC/350 VDC.
- MPP Voltage Range: 350VDC~850 VDC.
- Number of MPP Trackers/Maximum Input Current: 2/A:37.65A , B: 18.6A
Grid Output (AC)
- Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
- Output Voltage Range: 184 -264.5 VAC per phase
- Nominal Output Current: 21.7A per phase
- Power Factor: >0.99.
Efficiency
- Maximum Conversion Efficiency (DC/AC): 96%.
- European Efficiency @ Vnominal: 95%.
Off-Grid Operation
AC Input
- AC start-up Voltage/Auto Restart Voltage: 120-140 VAC per phase/180 VAC per phase.
- Acceptable Input Voltage Range: 170-280 VAC per phase.
- Max. AC Input Current: 40A.
PV Input (DC)
- Max. DC Voltage: 900 VDC.
- MPP Voltage Range: 350 VDC~850 VDC.
- Number of MPP Trackers/Max. Input Current: 2/A: 37.65A, B:18.6A
Battery Mode Output (AC)
- Nominal Output Voltage: 230 VAC (P-N)/400 VAC(P-P).
- Output Waveform: Pure Sinewave.
- Efficiency (DC to AC): 91%.
Hybrid Operation
PV Input (DC)
- Nominal DC Voltage/Max. DC Voltage: 720 VDC/900.
- Start-up Voltage/Initial Feeding Voltage: 320 VDC/ 350 VDC.
- MPP Voltage Range: 350 VDC~850 VDC.
- Number of MPP Trackers/Max. Input Current: 2/A: 37.65A , B: 18.6A
Grid Output (AC)
- Nominal Output Voltage: 230 VAC (P-N)/400 VAC(P-P).
- Output Voltage Range: 184-264.5 VAC per phase.
- Nominal Output Current: 21.7A per phase.
AC Input
- AC Start-up Voltage/Auto Restart Voltage: 120-140 VAC per phase/180 VAC per phase.
- Acceptable Input Voltage Range: 170-280 VAC per phase.
- Max. AC Input Current: 40A.
Battery Mode Output (AC)
- Nominal Output Voltage:230 VAC (P-N)/400 VAC(P-P)
- Efficiency (DC to AC): 91%.
Battery & Charger
- Nominal DC Voltage: 48 VDC.
- Max. Charging Current: Default 60A, 5A-300A (Adjustable).
General
Physical
- Dimension (D x W x H) (mm): 219 x 650x 820
- Net weight (kgs): 62
Interface
- Communication Port: RS-232/USB and Dry contact
- Intelligent Slot: Optional SNMP, Modbus and AS-400 cards available.
Environment
- Humidity: 0~90% RH (Non-condensing).
- Operating Temperature: -10 to 55 °C
- Altitude: 0-1000 m.
**These figures may vary depending on different AC voltage and country requirements. Power derating 1% every 100m when altitude is over 1000m. Product specifications are subject to change without further notice.
Reviews